CSCA Physics · Electromagnetism · Section 8 of 12
Electromagnetic Induction (Faraday’s Law)
Magnetic Flux
Φ = BA cosθ, where B is field strength, A is area, θ is angle between B and the area normal. Unit: Weber (Wb).
Chinese textbooks write the area S, the number of turns n, the length of a rod l and the induced EMF E: Φ = BS cosθ, E = nΔΦ/Δt, E = Blv.
Faraday’s Law
An EMF (感应电动势) is induced whenever the magnetic flux (磁通量) through a circuit changes; an induced current (感应电流) flows only if the circuit is closed. A loop moving through a uniform field without its flux changing has no induced current. The EMF depends on how fast Φ changes, not on Φ itself: a rotating coil has Φ = 0 when its plane is parallel to B, and that is exactly when its EMF is largest. Faraday’s law (法拉第电磁感应定律): ε = −N(ΔΦ/Δt). The negative sign (Lenz’s law) means the induced current opposes the change. N is number of turns.
Ways to Change Flux
Change B, change A (move conductor), or change θ (rotate coil). Changing the number of turns N does not change the flux; it multiplies the EMF. A straight rod of length L moving at speed v perpendicular to B sweeps out area, giving the motional EMF (动生电动势) ε = BLv. Generators work by rotating a coil in a magnetic field: ε = NBAω sin(ωt).
Beyond the syllabus: the CSCA syllabus lists only Faraday’s law and Lenz’s law for induction, so the self-inductance, mutual inductance and back-EMF paragraphs below are background reading, not required.
Self-inductance (自感). A changing current in a coil changes its own flux, which induces an EMF opposing that change: ε = −L(dI/dt). The constant L is the inductance, measured in henries — the unit is the henry, symbol H, and it depends on the coil itself (its size, shape, number of turns and whether it has an iron core), not on the current. Energy is stored in the magnetic field as U = ½LI², the magnetic counterpart of ½CV² for a capacitor.
Mutual inductance is the same effect between two coils: a changing current in the first induces an EMF in the second, ε₂ = −M(dI₁/dt). This is exactly how a transformer works.
Back EMF. A spinning motor is also a generator: its rotation induces an EMF that opposes the supply voltage. That is why the current surges when a motor first starts, before it is turning fast enough to generate much back EMF, and why a stalled motor can burn out.
Key takeaway: Φ = BA cosθ. ε = −NΔΦ/Δt. Induced EMF opposes flux change (Lenz’s law).
Key Formulas
- Φ = BAcosθ
- ε = −NΔΦ/Δt
- ε = BLv (motional)
Worked Example 1
Q: Coil of 100 turns, area 0.01 m². B changes from 0.5 T to 0 in 0.02 s. EMF?
A: ΔΦ = 0.5×0.01 = 0.005 Wb. ε = 100×0.005/0.02 = 25 V.
Worked Example 2
Q: Rod 0.5 m moves at 4 m/s perpendicular to B = 0.3 T. EMF?
A: ε = BLv = 0.3×0.5×4 = 0.6 V.
Worked Example 3
Q: Flux through a coil: Φ = 0.02sin(100πt). Peak EMF for 50 turns?
A: εmax = NΦ₀ω = 50×0.02×100π = 314 V.
Exam Tips
Use magnitude for EMF calculations.
ε = BLv for motional EMF.
Lenz’s law: induced opposes change.
Common Mistakes
Forgetting N (number of turns).
Wrong angle in Φ = BAcosθ.
Not using rate of change.