CSCA Physics · Electromagnetism · Section 10 of 12
AC Circuits & Transformers
Beyond the syllabus: the CSCA syllabus lists DC circuits and electromagnetic induction but not alternating current, transformers, reactance, impedance or resonance. This lesson is background reading and is left out of our mock papers.
Alternating Current
AC voltage: V(t) = V₀ sin(ωt). The RMS (root mean square) values are: Vrms = V₀/√2, Irms = I₀/√2. Average power in a resistor: P = Vrms × Irms = V₀I₀/2 (with a capacitor or inductor in the circuit, P = Vrms Irms cos φ; see below).
Transformers
A transformer changes AC voltage using electromagnetic induction. Vs/Vp = Ns/Np = Ip/Is. Step-up: Ns > Np (increases voltage). Step-down: Ns < Np. Ideal: Pin = Pout.
Power Transmission
High voltage reduces current for same power (P = IV), reducing I²R losses in transmission lines. Step up at power station, step down at destination.
Reactance: Resistance That Depends on Frequency
A resistor opposes AC exactly as it opposes DC. Capacitors and inductors are different — they oppose AC by an amount that depends on how fast it alternates, and that opposition is called reactance, measured in ohms:
- Capacitive reactance
XC = 1/(ωC) = 1/(2πfC)— falls as frequency rises, so at very high frequency a capacitor behaves like a plain wire, and at DC (f = 0) like a break in the circuit. - Inductive reactance
XL = ωL = 2πfL— rises with frequency, so an inductor is the mirror image: a wire at DC, a block at high frequency.
Neither component dissipates any energy. Over a complete cycle each stores energy and gives it all back, so the average power in a pure capacitor or a pure inductor is zero — the current flowing in them is called wattless current.
Phase and Impedance
In a capacitor the current LEADS the voltage by 90°; in an inductor the current LAGS by 90°. The mnemonic is CIVIL: in a C, I leads V; V leads I in an L. Because these are 90° out of step with the resistor’s voltage, they cannot simply be added — they combine like the sides of a right-angled triangle:
Z = √(R² + (XL − XC)²)
which reduces to Z = √(R² + XL²) for an RL circuit and Z = √(R² + XC²) for RC. The phase angle between voltage and current follows from the same triangle, tan φ = (XL − XC)/R, and only the resistor consumes power:
P = Vrms Irms cos φ, where cos φ = R/Z is the power factor
The product Vrms Irms on its own is the apparent power S, measured in volt-amperes rather than watts, and only the fraction cos φ of it is real.
Resonance
XL rises with frequency while XC falls, so at one particular frequency they are equal and cancel:
f₀ = 1/(2π√(LC))
At that frequency the impedance drops to its minimum, Z = R, the current peaks, the phase angle is zero and the power factor is 1. This is how a radio selects a station: tuning changes C until f₀ matches the broadcast frequency. The sharpness of the peak is measured by the Q factor, which is the ratio of the resonant frequency to the bandwidth, Q = f₀/Δf — a high Q means a narrow, selective peak.
Key takeaway: Vrms = V₀/√2. Transformer: Vs/Vp = Ns/Np. High V reduces transmission losses.
Key Formulas
- Vrms = V₀/√2, Irms = I₀/√2
- Vs/Vp = Ns/Np = Ip/Is
- Ploss = I²R
Worked Example 1
Q: V₀ = 340 V. Find Vrms.
A: Vrms = 340/√2 = 240 V.
Worked Example 2
Q: Transformer: 100 turns primary, 500 turns secondary. Vp = 20 V. Vs?
A: Vs = 20 × 500/100 = 100 V.
Worked Example 3
Q: Power station outputs 10 MW. Compare losses at 10 kV vs 100 kV.
A: At 10kV: I = 1000A. At 100kV: I = 100A. Losses ∝ I², so 100× less at 100kV.
Exam Tips
RMS = peak/√2.
Ideal transformer: Pin = Pout.
Power loss = I²R in wires.
Common Mistakes
Using peak instead of RMS.
Confusing step-up/step-down.
Forgetting transformers only work with AC.